air conditioner blowing weakly

The main error codes of air conditioners

Modern air conditioning systems are technologically advanced and reliable. But any equipment has a service life, and it can be significantly reduced due to improper or untimely maintenance. This is especially true for split systems. They consist of many components that are interconnected. It is not surprising that one of the parts may break sooner or later.

When the split system fails, an error is displayed on the air conditioner. This is very convenient. But to accurately determine the cause of the breakdown, you need to be able to decipher the error codes of air conditioners. The whole difficulty lies in the fact that the same code can have a different meaning for each manufacturer.

If you still have the technical documentation for the air conditioner, you can find the decryption of the codes in it. But what if there are no documents? Read this article. In it, we list the main error codes from various manufacturers and tell you how to decipher them.

Please note! This article lists error codes for household split systems. Here you will not find codes for other types of air conditioners. You should understand that the list of errors of split systems and channel devices is different.

List of errors from various manufacturers

air conditioning does not work

The main error codes of air conditioners from different manufacturers are listed below.

Samsung

samsung logo

  • E464-the power module is overloaded;

  • E461-the compressor does not start;

  • E473-the compressor is blocked;

  • E466-incorrect voltage in the DC board module;

  • E221-the ambient air temperature sensor has failed or is not working properly;

  • E416-the system overheated;

  • E251-the temperature sensor has failed or is not working properly;

  • E468-the current sensor has failed or is not working properly;

  • E465-the compressor is not working properly;

  • E237-the thermal sensor winding is not working properly;

  • E202-connection is not established;

  • E458-the fan is not working properly;

  • E471-OTP is not working properly;

  • E467 – a failure occurred during the compressor rotation;

  • E469-the voltage sensor is not working properly;

  • E554-there was a leak of the refrigerating agent;

  • E472-AC voltage failure;

  • E121 — the indoor temperature sensor has failed or is not working properly;

  • E122-the evaporator temperature sensor has failed or is not working properly;

  • E154-the fan in the indoor unit is not working properly;

  • E101-connection is not established;

  • E186-MPI operation failed.

Ballu

  • E1 — the sensor of the indoor unit has failed or is not working properly;

  • E2-the capacitor temperature sensor has failed or is not working properly;

  • E3-the evaporator temperature sensor has failed or is not working properly;

  • E4-the sensor of the outdoor unit has failed or is not working properly;

  • E6-the outdoor unit is not working properly, the protection has been triggered;

  • E8-cleaning of the electrostatic filter is required;

  • P4-the evaporator temperature sensor has failed or is not working properly due to low / high temperature;

  • P5-the capacitor temperature sensor has failed or is not working properly due to low / high temperature;

  • P6-the heat exchanger is working with a delay, or the forced defrosting mode has been activated.

Dahatsu

  • E1 — increased pressure in the freon line;

  • E2-the heat exchanger in the indoor unit is frozen;

  • E3 — insufficient pressure in the circuit;

  • E4-excessive discharge temperature;

  • E5-excess current value in the compressor motor;

  • E6 — the connection between the outdoor and indoor unit is lost;

  • E8-automatic protection has been triggered;

  • F0-error f0 means that the temperature sensor has failed or is not working properly;

  • F1-error f1 means that the evaporator temperature converter has failed or is not working properly;

  • F2-the capacitor temperature sensor has failed or is not working properly;

  • F4 — the indoor air injection temperature converter has failed or is not working properly.

Electrolux

  • E1 – excessive pressure;

  • E2-the indoor unit is frozen;

  • E3 – insufficient pressure;

  • E4-the compressor has failed or is not working properly;

  • E5-overcurrent;

  • E6 – the connection between the outdoor and indoor unit is lost;

  • E7 – the selected mode does not work correctly in the internal block; – E8-error e8 means that the fan in the indoor unit has overloaded;

  • E9-the drainage tray is overflowing;

  • F0-an error f0 on the display means that the temperature sensor in the indoor unit has failed or is not working properly;

  • F1-the thermal sensor at the inlet of the heat exchanger in the indoor unit has failed or is not working properly;

  • F2-the thermal sensor in the middle of the heat exchanger in the indoor unit has failed or is not working properly;

  • F3-the thermal sensor at the outlet of the heat exchanger in the internal unit has failed or is not working properly;

  • F4 – the outdoor air temperature sensor has failed or is not working properly;

  • F5 – the outdoor unit’s temperature sensor has failed or is not working properly; — F6-error f6 means that the temperature sensor at the heat exchanger inlet of the outdoor unit has failed or is not working properly;

  • F7-the thermal sensor at the outlet of the heat exchanger in the outdoor unit has failed or is not working properly;

  • F8-the discharge temperature sensor of the 1st compressor has failed or is working incorrectly;

  • F9-the discharge temperature sensor of the 2nd compressor has failed or is working incorrectly;

  • FA-the crankcase temperature sensor of the first compressor has failed or is working incorrectly;

  • FB-the crankcase temperature sensor of the second compressor has failed or is working incorrectly;

  • FC-the high pressure sensor has failed or is not working properly;

  • FD-the low pressure sensor has failed or is not working properly;

  • EN-the additional heater has failed or is not working properly.

Daikin

Daikin air conditioner

  • A0-protection has been triggered;

  • A1-the printed circuit board has failed or is not working properly;

  • A2-the fan motor is blocked;

  • A3 – increased water level in the drainage;

  • A4-the heat exchanger has failed or is not working properly;

  • A5 – the temperature in the heat exchanger is increased/decreased;

  • A6-the fan motor has overloaded;

  • A7-the shutter drive has failed or is not working properly;

  • A8-overcurrent;

  • A9-the expansion valve has failed or is not working properly;

  • AA-the engine has overheated;

  • The AH filter is dirty;

  • The AC system is running » idle»;

  • AJ-the performance is below the required value;

  • AE-insufficient water supply;

  • The AF humidifier has failed or is not working properly;

  • C3 — the sensor of the drainage system has failed or is not working properly;

  • C4-the thermal sensor of the first heat exchanger has failed or is not working properly;

  • C5-the thermal sensor of the second heat exchanger has failed or is working incorrectly;

  • C6-the fan motor has overloaded;

  • C7-the shutter drive sensor has failed or is not working properly;

  • C8-the input current sensor has failed or is not working properly;

  • C9 – the inlet air thermistor has failed or is not working properly;.

  • CA-the air thermistor at the outlet has failed or is working incorrectly;.

  • CH – increased contamination, cleaning and disinfection is required;

  • CC-the humidity sensor has failed or is not working properly;

  • CJ-the temperature sensor on the remote control has failed or is not working properly;

  • The CE radiation sensor has failed or is not working properly;

  • The CF-high pressure sensor has failed or is not working properly.

General Climate

  • E2-the indoor air temperature sensor has failed or is not working correctly;

  • E3-the evaporator temperature sensor has failed or is not working correctly;

  • E4-the capacitor temperature sensor has failed or is not working correctly;

  • E5-the drainage pump has failed or is not working properly;

  • E6-problems with the protection of the outdoor unit;

  • E7-the volatile memory module has failed or is not working properly;

  • E8-the drainage tray is overflowing, the protection has been activated;

Hisense

  • 1-the thermal sensor of the heat exchanger in the outdoor unit has failed or is working incorrectly;

  • 2-the temperature sensor of the compressor discharge line has failed or is not working correctly;

  • 5-the IPM module is faulty, the protection has been triggered;

  • 6-protection has been triggered in the AC network due to high or low voltage;

  • 7 — there is no connection between the outdoor and indoor unit;

  • 8-the system is overloaded, the protection has worked;

  • 10-the connection between the control circuits and the drive circuits is lost;

  • 11-the memory module in the outdoor unit has failed or is working incorrectly;

  • 12 — the outdoor temperature is too low, the protection has been triggered;

  • 13-the compressor temperature is too high, the protection has been triggered;

  • 14 — the air temperature sensor on the street has failed or is working incorrectly;

  • 15-the compressor overheated, the protection worked;

  • 16-in the heating mode, the protection was triggered, because the heat exchanger in the internal unit overloaded and froze;

  • 17-reactive power compensation has been triggered;

  • 18-the DC compressor has failed or is working incorrectly;

  • 19-the compressor drive has failed or is working incorrectly;

  • 20-operation of the device for protecting the fan motor of the outdoor unit from working with a braked rotor

Hyundai

  • 0-the volatile memory module has failed or is not working properly;

  • E1 – there is no connection between the outdoor and indoor unit;

  • E2-the thermal sensor in the outdoor unit has failed or is not working correctly;

  • E3-the fan motor located in the indoor unit has failed or is working incorrectly;

  • E4-the temperature sensor in the room has failed or is working incorrectly;

  • E5-the evaporator temperature sensor has failed or is not working correctly;

  • EU-a leak of the refrigerating agent was detected.

LG

algy лого

  • 01 — the air temperature sensor has failed or is not working correctly. A circuit break is also possible;

  • 02-the evaporator temperature sensor has failed or is not working correctly. A circuit break is also possible;

  • 03-the connection between the indoor unit and the drive console is lost;

  • 04-the drainage pump has failed or is working incorrectly, or the condensate sensor has failed or is working incorrectly;

  • 05-the connection between the outdoor and indoor unit is lost;

  • 06-the temperature sensor in the outdoor unit has failed or is working incorrectly;

  • 07-the blocks work in different modes;

  • HL-the opening of the float sensor is fixed;

  • CL-child protection mode is enabled;

  • Po-Jet Cool mode works.

Mitsubishi Electric

mitsubishi logo

  • P1-the input sensors are not working properly;

  • P2-the sensor at the TN5 heat exchanger has failed or is working incorrectly;

  • P4-the drain pan is full;

  • P5-the drainage pump is not working properly;

  • P6-overheating or, conversely, freezing is detected;

  • P9-the sensor at the TN2 heat exchanger has failed or is working incorrectly;

  • RA-compressor operation is stopped;

  • E0, E3 – no connection with the remote control;

  • E1, E2-the control board has failed or is not working properly;

  • E9, EE – there is no connection between the outdoor and indoor unit;

  • U1, Ud-the system overheated, the protection worked;

  • U2 – not enough refrigerating agent;

  • U3, U4-the temperature sensor in the outdoor unit has failed or is not working properly;

  • U5-the temperature of the capacitor is lowered/increased;

  • U6-the power module has failed or is not working properly, or the compressor is stopped;

  • U7 – insufficient pressure or lack of refrigerating agent is recorded in the supercharger;

  • U8-the fan motor located in the outdoor unit has failed or is working incorrectly;

  • U9, UH-the current sensor has failed or is not working properly, or the supply voltage is insufficient/increased;

  • UF – an overcurrent has occurred, or the compressor does not work;

  • UP-compressor overload;

  • Fb-the control board of the outdoor unit has failed or is not working properly.

Toshiba

toshiba logo

  • 00-0C-the temperature sensor inside the air conditioner has failed or is working incorrectly, or there was a failure on the indoor unit board;

  • 00-0d-the thermal sensor on the radiator has failed or is working incorrectly, or there was a failure on the control board;

  • 00-11 — the fan board or motor has failed/is not working properly;

  • 00-12-the control board has failed or is not working properly;

  • 01-04-incorrect interblock connection, or the board/fuses on the board are faulty;

  • 01-05-there was a failure in the inverter board;

  • 02-14-the inverter is overloaded;

  • 02-16-a short circuit is recorded in the compressor windings;

  • 02-17-the current sensor has failed or is not working properly;

  • 02-18-the temperature sensor has failed or is not working properly;

  • 02-19 — the thermal sensor on the board has failed or is working incorrectly;

  • 02-1A-the engine has failed or is not working properly;

  • 02-1b-the board has failed or is not working properly;

  • 02-1C-the compressor did not start;

  • 03-07-there is not enough refrigerating agent, or the inverter board has failed or is working incorrectly;

  • 03-1d-the compressor has failed or is not working properly;

  • 03-1E-the sensor on the suction tube has failed or is not working properly;

  • 03-1F — there is insufficient voltage in the compressor, or the refrigeration circuit is overloaded;

  • 03-08 — the four-way valve has failed or is working incorrectly.

Neoclima

Neoclima NS/NU-HAX18R

  • E0-the indoor and outdoor unit are connected incorrectly;

  • E1-the connection between the indoor unit and the controller is lost;

  • E2-the thermal sensor has failed or is not working properly;

  • E3-the temperature sensor of the condenser tube has failed or is working incorrectly;

  • E8-the heating system has failed or is not working properly;

  • F0 — the fan in the indoor unit has failed or is not working properly;

  • F2 — protection of the outdoor unit;

  • F3 — overpressure, protection triggered;

  • F4 — insufficient pressure, protection has been triggered;

  • F5 — overabundance of water, protection has worked;

  • F8-the outdoor unit overheated, the protection worked;

  • F9-incorrect phase sequence;

  • P4-the compressor has failed or is not working properly (if the device is an inverter);

  • P6-the volatile memory module in the outdoor unit has failed or is not working properly.

Zanussi

  • E2-the temperature sensor in the room has failed or is working incorrectly;

  • E3 — the sensor on the evaporator has failed or is not working properly;

  • E5-the capacitor sensor has failed or is not working properly;

  • F5-switch-the float in the drainage tray has failed or is not working properly;

  • F2 — there are problems in the operation of the outdoor air conditioner unit;

  • P6-the volatile memory module has failed or is not working properly.

These were the main error codes of air conditioners for different manufacturers. We have listed only the most popular brands. If your split system has issued one of the errors, contact the service center.

Results

Every master should know the basic error codes of air conditioners from various manufacturers. Also, this information will be useful for the user of split systems. If the device gives you an error, you can easily decipher it and report it to the master, thereby simplifying his work.

To correct the error of the air conditioner, you need experience and knowledge. Therefore, we do not recommend that the user carry out repairs on their own. Contact the service center for help. A professional master will quickly decipher the error codes of the air conditioner and quickly eliminate the breakdown.

Are you an experienced craftsman? Tell us about your experience of deciphering and correcting errors in the air conditioner. Your tips and recommendations will be useful for many readers. Also, do not forget to share your favorite articles on your social networks. We wish you good luck!