malfunctions 2

Error codes of Daikin air conditioners

Daikin brand air conditioners are one of the most popular on the market. They can boast of rich functionality, modern appearance and durability.

But do not forget that the split system consists of many components that can fail during operation. When a particular component stops working correctly, the air conditioner reports this by displaying the so-called error code on the display. It can be decrypted and thus find out what happened to the device.

This article presents all the main error codes of the Daikin air conditioner. Every user should know about them. If one of the errors occurs, contact the service center for help. Do not attempt to perform repairs yourself.

We have divided the article into several parts. You will learn about errors that occur in the operation of both the outdoor and indoor (wall) units. You will also learn about common malfunctions.

Indoor unit errors

artel air conditioner error codes

Let’s start with the errors that occur in the operation of the internal (wall) unit.

A0

  • The general protective device worked

  • An error occurred in the operation of the protection device

  • The protective device has been activated (general) External protection device error. Malfunction of the indoor unit circuit board. Faulty connector connection

A1

The printed circuit board of the wall unit has failed

A2

  • The fan motor is blocked

  • The fan motor is out of order

A3

  • Overflowing drainage

  • The drainage pump is out of order

  • The system that controls the flow level is faulty

A4

The heat exchanger failed due to high/low temperature.

A5

The heat exchanger temperature is too high/low.

A6

  • The fan motor has overloaded

  • The fan motor of the wall unit has failed

  • The fan motor is blocked

A7

  • The louver drive is out of order

  • The motor valve is faulty

  • Engine malfunction

A8

General overcurrent.

A9

Malfunction of the expansion valve.

AA

The heater overheated.

AN

The air filter is dirty.

AS

The machine is idling.

AJ

  • Incorrect performance setting of the wall unit

  • Incorrect switching of the power adapter

AE

Lack of water.

AF

  • Malfunction in the humidifier

  • Clogged drain

  • Incorrect installation of the drain pipe

C0

General problems with the sensor.

C1

There is no signal between the wall unit and the fan.

C3

Malfunction of the sensor that monitors the water level in the drainage.

C4

The sensor measuring the temperature at the first heat exchanger failed.

C5

The sensor measuring the temperature at the second heat exchanger failed.

C6

The fan motor has overloaded.

C7

  • The sensor responsible for the operation of the louver drive has failed

  • The shutter switch/switch does not work

  • The drive motor has failed

C8

The input current sensor does not work.

C9

The sensor-thermistor of the input air failed.

SA

The sensor-thermistor of the output air failed.

SN

A sensor measuring the level of contamination has been triggered.

SS

The sensor that measures the humidity level has failed. There may also be malfunctions in the operation of the remote control thermistor.

CE

The radiation sensor failed.

CF

The high-pressure sensor failed.

Outdoor unit errors

outdoor split system unit

Do not forget about the outdoor unit, it also has breakdowns.

E0

The general protective device worked. A fuse failure is also possible.

E1

The circuit board in the outdoor unit has failed.

E3

The sensor detecting the overpressure was activated.

E4

The sensor detecting insufficient pressure acted.

E5

Lack of refrigerating agent or general overload of the compressor motor.

E6

Excess current. The compressor motor is blocked. The pressure is too high.

E7

The fan failed.

E8

Current overload (either general or in case of compressor failure).

E9

The electronic expansion valve is faulty.

EA

The four-way valve is faulty or not working properly.

AN

The pump is blocked.

EU

Excessive or insufficient water temperature. A general malfunction of the outdoor unit is also possible.

RSV

The thermistor is out of order.

EJ

The add-on worked.protective device.

HER

The water level in the drainage is excessive or insufficient.

EF

The unit responsible for heat storage is faulty.

BUT

  • Compressor sensor system is out of order

  • Defective printed circuit board

H1

The sensor that measures the temperature of the air has failed.

H2

The sensor responsible for powering the system has failed.

H3

The sensor that tracks the increase in pressure has failed.

H4

The sensor that tracks the pressure drop has failed.

H5

  • Compressor failed

  • The overload sensor has acted

  • Compressor motor overload thermistor failed

H6

  • The lock sensor was activated

  • The compressor has overloaded or failed

H7

The fan has overloaded or failed.

H8

The power transistor has failed, or the sensor tracking the input voltage has tripped.

N9

The external thermistor is out of order.

ON

The sensor that keeps the output air out has been activated.

NN

The water pump is blocked.

NS

The hot water thermostat is out of order.

HE

A sensor monitoring the drainage level has been triggered.

HF

There was a failure in the operation of the unit responsible for heat storage.

HJ

The sensor that monitors the water level is faulty, not detected, or not working properly.

F0

The first and second protective devices were activated.

F1

In the first system, the protection worked. device.

F2

In the second system, the protection worked. device.

F3

The temperature of the discharge pipe is increased.

F6

The heat exchanger temperature is elevated, or the filter in the wall unit is clogged.

FA

The discharge pressure is excessive or insufficient.

FN

The oil temperature is excessive.

FS

The suction pressure is excessive or insufficient.

FE

The oil pressure is excessive or insufficient.

FF

The oil level is excessive or insufficient.

J0

The thermistor is out of order.

J1

The sensor responsible for monitoring the pressure level has failed.

J2

The sensor responsible for monitoring the current level has failed.

J3

The sensor responsible for monitoring the temperature of the discharge pipe has failed.

J4

The insufficient pressure sensor failed.

J5

The thermistor on the suction pipe has failed.

J6

The thermistor on the heat exchanger has failed.

J7

The thermistor on the heat exchanger has failed.

J8

The thermistor on the liquid pipe failed.

J9

The thermistor on the gas pipe failed.

JA

The sensor responsible for monitoring the discharge failed.

JN

The sensor responsible for monitoring the oil temperature has failed.

JC

The sensor responsible for monitoring the suction pressure has failed.

JE

The sensor responsible for monitoring the oil pressure has failed.

JF

The sensor responsible for monitoring the oil level has failed.

L0

The inverter is disconnected, there are malfunctions.

L3

The fan of the outdoor unit failed, which caused the temperature in the control box to rise.

L4

The inverter overheated.

L5

The power transistor is faulty, an overcurrent has occurred.

L6

There was a short circuit of the compressor, or there is a malfunction in the operation of the coil. Short-term AC overload is also possible.

L7

Excess input current indicator.

L8

The compressor is overloaded, or the electronic relay is running with a delay.

L9

The compressor is blocked, or the machine is running with a delay.

LA

The power supply and / or power transistor failed.

LC

Communication with the outdoor unit inverter is lost.

P0

Lack of refrigerating agent or gas due to icing.

P1

No phase.

P3

An excessive temperature is detected inside the control unit.

P4

The sensor responsible for monitoring the radiator temperature has failed.

P5

The sensor responsible for monitoring the DC current has failed.

P6

The sensor responsible for monitoring the output current has failed.

P7

Excess input current.

RA

The humidifier has a broken heater wire.

RS

Empty cylinder of the refrigerating agent.

RE

The auto-loading of the refrigerating agent charge is almost complete.

PH

The heater is out of order.

PJ

Incorrect performance setting.